WELD.blog
Welding TechniquesNov 16, 2026 · 14 min read

Welding Positions Explained: 1G to 6G

Learn what welding positions 1G 2G 3G 4G 5G and 6G mean, how they map to ISO 6947 codes, and how test positions relate to welder qualification.

WELD.blog Editorial
WELD.blog Editorial
Editorial Team · Content curated from industry standards (AWS, TWI) and peer-reviewed sources
Welding Positions Explained: 1G to 6G

Anyone who opens a welder qualification record, a procedure sheet or a job advert quickly runs into codes like 1G, 3F or 6G. These welding positions 1G 2G 3G 4G and their pipe cousins 5G and 6G look like jargon, but they describe something simple: where the joint sits in space and how gravity acts on the molten pool. That single fact drives the technique, the amperage, the filler metal choice and the difficulty of the test.

This guide explains what each code means, how the American letter-and-number system relates to the ISO 6947 codes used in Europe and elsewhere, why vertical and overhead work behaves so differently from flat work, and how positions fit into qualification. Along the way it covers common mistakes and practical ways to practice.

What a Welding Position Actually Describes

A welding position is the orientation of the weld axis and the weld face relative to the horizontal. Two angles matter: the slope of the weld axis and the rotation of the weld face around that axis. Every named position is a particular combination of the two.

Gravity is the reason the classification exists. Molten steel is a liquid, and in the flat position it sits neatly in the joint. In every other position it wants to sag, run or drip, so the welder has to control heat input, travel speed and bead shape much more carefully.

Positions are also used for two different purposes:

  • Test positions are the orientations in which a welder or a procedure is qualified, usually on a plate or pipe coupon.
  • Production positions are the orientations actually met on the job, which may be more varied than the test.

The ISO 6947 standard on welding positions covers both testing and production use for butt and fillet welds in all product forms, which is why the same position codes appear on qualification certificates and on fabrication drawings.

The Letter and Number System: G Means Groove, F Means Fillet

In the American system, the number gives the orientation and the letter gives the joint type.

  • G stands for groove weld, which covers butt joints and similar joints where the weld fills a prepared edge.
  • F stands for fillet weld, the triangular weld in a T-joint or lap joint.

The numbers 1 to 4 run from the easiest orientation to the hardest on plate: flat, horizontal, vertical, overhead. For pipe, 5G and 6G describe a fixed pipe that the welder must work around.

Code Joint Orientation Typical difficulty
1G Groove, plate Flat Lowest
2G Groove, plate Horizontal (weld axis horizontal, plate vertical) Moderate
3G Groove, plate Vertical High
4G Groove, plate Overhead High
5G Groove, pipe Pipe axis horizontal, fixed in place High
6G Groove, pipe Pipe fixed at roughly 45 degrees Highest of the common tests
1F to 4F Fillet Flat, horizontal, vertical, overhead Rises with the number

The table gives the usual textbook picture. Always check the governing code for the exact definition, because tolerances on angles and rules for rotating or fixed coupons are written into the standard.

Plate Groove Positions: 1G to 4G

1G: Flat

In 1G, the plate lies flat and the weld is made from above. The weld axis is horizontal and the face is roughly horizontal too. Gravity holds the pool in the joint, penetration is easy to see and control, and deposition rates can be high.

This is where most beginners start, and for good reason. It is also where much production work in a shop is arranged to happen, because fixtures and positioners exist to bring joints into the flat position.

Flat does not mean careless. The common faults are lack of fusion at the sidewalls, slag trapping between passes and burn-through on the root, all of which are about technique rather than gravity.

2G: Horizontal

In 2G, the plate stands upright and the weld runs horizontally across it. The pool tends to sag toward the lower plate, so the bead can develop an overlap at the bottom and an undercut at the top.

Good practice is to use a slightly upward electrode or torch angle, keep the pool small and stack multiple narrower stringer beads rather than one wide weave. Travel speed becomes more important than in 1G, because stopping to look at the pool lets it droop.

3G: Vertical

In 3G, the plate is upright and the weld runs up or down the joint. This is the first position where technique has to change noticeably.

  • Uphill progression gives deeper penetration and a thicker bead. It is the usual choice for structural and code work, but it demands a controlled weave or a shelf-building technique so the pool does not run.
  • Downhill progression is faster and shallower. It is typically restricted to thin material and non-critical joints, and many codes and procedures do not allow it for structural groove welds.

With a stick electrode, vertical-up work often uses a "whip" or a triangular weave, and the electrode type matters. If you want the process background, the guide on what is stick welding explains how flux-coated electrodes behave in the pool. For wire processes, short-circuit transfer and lower settings keep the pool manageable out of position.

4G: Overhead

In 4G, the plate is above the welder and the weld is made from beneath. Gravity pulls the pool, spatter and slag away from the joint and toward the welder, which makes this the most physically uncomfortable plate position.

Keep the arc short, the pool small and the heat input restrained. Because molten metal and sparks fall downward, protective clothing needs extra attention: closed collars, sleeves that cover the wrists, a head covering under the helmet and boots with covered tops. Overhead work is also a reminder that fire prevention rules apply as fully as ever.

Pipe Positions: 5G and 6G

Pipe adds a complication: the joint curves around the weld axis, so the effective position changes continuously as the welder moves around the circumference.

5G: Pipe Axis Horizontal, Fixed

In 5G, the pipe lies horizontally and does not rotate. The welder starts at the bottom and works upward on each side, passing through flat, vertical and overhead orientations in a single weld.

That continuous change is the real difficulty. Amperage, angle and travel speed that suit the top of the pipe will sag at the bottom, so welders adjust constantly and often rehearse the hand and body movements before striking an arc. A 5G test is a common benchmark for pipe and tube welders, and it is the position behind many pipeline, power and process piping jobs.

6G: Pipe Fixed at 45 Degrees

In 6G, the pipe is fixed at about 45 degrees to the horizontal. The joint then contains flat, horizontal, vertical and overhead segments, all at an inclined angle, so the welder has to deal with a combination of conditions.

Because of this, 6G is widely treated as one of the hardest standard test positions. It is also a valuable one, since a welder who can produce sound welds in 6G has demonstrated control in nearly every orientation.

6GR: The Restricted Variant

Some codes add a restriction ring around the test joint, described as 6GR in American practice. The ring limits access and simulates a tight weld close to an obstruction, such as a branch connection, a nozzle or a sleeve. It is harder than plain 6G because the welder cannot move the torch or electrode freely.

2G on Pipe

A fixed pipe with a vertical axis is sometimes tested as a 2G pipe position, with the weld running horizontally around it. It is not mentioned as often as 5G and 6G, but it appears in some qualification schemes and is worth knowing about.

Fillet Positions: 1F to 4F

Fillet welds follow the same logic as groove welds, but the geometry is a corner rather than a prepared gap.

  • 1F is flat: the joint is arranged so the fillet sits in a roughly 45-degree trough.
  • 2F is horizontal: the weld axis is horizontal and the plates are one flat, one vertical.
  • 3F is vertical: the weld runs up or down a vertical T-joint.
  • 4F is overhead: the weld is made on the underside of a horizontal plate.

Fillet welds are simpler to deposit in many ways, but they have their own pitfalls. Uneven leg lengths, insufficient throat and undercut on the vertical leg are common, particularly in 2F.

The same families of codes also deal with pipe fillet positions and branch joints, which add their own variations and sometimes their own test coupons.

ISO 6947 Position Codes

Outside North America, welders and procedures usually use the codes in ISO 6947, which describes working positions with letters instead of numbers. The current edition was published in 2019 and was last reviewed and confirmed in 2024.

The commonly quoted correspondences are approximate, not exact:

American ISO 6947 (approximate) Description
1G PA Flat
2G PC Horizontal
3G (uphill) PF Vertical up
3G (downhill) PG Vertical down
4G PE Overhead
1F PA Flat fillet
2F PB Horizontal fillet
3F PF or PG Vertical fillet
4F PD Overhead fillet
5G PH or PJ Pipe, horizontal axis, uphill or downhill
6G H-L045 or J-L045 Pipe inclined at 45 degrees, uphill or downhill

Treat this table as an orientation aid. If you are filling in a certificate or a procedure, copy the code from the standard that applies to the work, not from a summary. The ISO system also separates uphill and downhill progression explicitly, which the American numbers do not.

Why Positions Change Technique

The practical differences between positions come down to a handful of physical effects.

Pool control

In flat, a large pool is stable. Out of position, a large pool is a liability. Welders reduce amperage, use smaller diameter electrodes or wire, and build the weld from multiple small passes.

Penetration and fusion

Vertical-up and overhead work tend to produce less predictable sidewall fusion. Techniques such as a slight pause at the edges of a weave give the sidewalls time to melt.

Process and consumable choice

Not every process is equally happy in every position. Spray transfer in MIG is usually a flat and horizontal tool, while short-circuit transfer and pulsed modes are used out of position. Some flux-cored wires are specifically designed to be all-position, while others are intended for flat and horizontal fillets only. Always check the consumable datasheet and the procedure.

Ergonomics

Body position affects weld quality. A welder who is stretched out, has no support for the hand and cannot see the pool will produce poor welds regardless of technique. Setting up the test coupon at a comfortable height, resting the elbow or wrist and checking the lighting often matter more than people expect.

Heat input and metallurgy

Out-of-position welding often uses lower heat input and more passes, which affects interpass temperature and cooling rate. These are procedure matters, covered further in the guide on how to read a WPS, where position is one of the variables that appear on the sheet.

Positions and Welder Qualification

Positions matter most when a welder moves from practice to certification. A test is carried out in a specific position and, if passed, qualifies the welder for a defined range of positions on production work.

The principle of qualified range

In general, a harder test qualifies a welder for easier positions, but not the other way around. In the American system, for example, testing in a flat groove position qualifies for flat work only, while testing in vertical and overhead groove positions on plate can cover all plate positions for groove and fillet welds. A pipe test in the 6G position is commonly used to cover a wide range of pipe and plate work.

Do not rely on these rules of thumb for real work. The exact range depends on:

  • the code in use, such as AWS D1.1, ASME Section IX, API 1104 or ISO 9606-1
  • the joint type, groove or fillet
  • the product form, plate, pipe or box tube
  • the pipe diameter, wall thickness and process
  • any additional restrictions in the project specification

The AWS D1.1 code is the structural steel code of the American Welding Society, and its welder qualification tables spell out which test positions qualify which production positions. ISO 9606-1 sets out the corresponding rules for fusion welding of steels under the ISO system.

How tests differ across systems

The American and ISO systems do not map perfectly onto each other. Each uses its own coupon dimensions, test positions, essential variables and acceptance criteria. For a detailed look at how the certification systems compare, see the comparison of AWS vs ISO 9606.

Choosing the position to test in

The right position depends on the work you want to do.

  1. Structural or fabrication shop work: plate tests in 3G and 4G are the usual route to all-position qualification on plate.
  2. Pipeline, power and process piping: pipe tests in 5G or 6G are the norm, often with a specific process and root pass technique.
  3. Light fabrication and repair: a flat or horizontal qualification may be enough if the work can be arranged to avoid other positions.

Employers, inspectors and clients normally decide which qualification they need. If you are planning a career, the overview of how to become a certified welder covers the broader route from training to test.

Common Mistakes by Position

Most test failures have patterns. Knowing them lets you practice deliberately.

  • Flat: inconsistent travel speed, poor sidewall tie-in and unfused root faces.
  • Horizontal: sagging at the bottom edge of the bead, undercut at the top edge and oversized single passes.
  • Vertical: letting the pool get too large, wide weaves with slag inclusions and incorrect progression direction.
  • Overhead: too much heat, drooping beads and poor visibility from awkward posture.
  • Pipe: changing travel speed and angle too late, starting and stopping poorly at the clock positions, and root passes that are inconsistent around the circumference.
  • Fillet: unequal legs, inadequate throat and missing the root corner.

Safety Out of Position

Out-of-position work has some extra hazards on top of the normal welding ones. OSHA's overview of welding, cutting and brazing lists health hazards such as metal fumes and ultraviolet radiation, and safety hazards such as burns, eye damage and electric shock, and notes that many of them can be controlled with proper work practices and personal protective equipment.

For vertical and overhead positions in particular:

  • Wear flame-resistant clothing with covered collars and cuffs, and keep pockets closed so sparks cannot lodge in them.
  • Use a head covering and ear protection when sparks may fall toward the neck and ears.
  • Check the area for combustible materials beneath you, since sparks can travel a long way when falling. OSHA's general requirements for welding include removing or guarding fire hazards, and not welding if they cannot be controlled.
  • Pay attention to fume exposure in awkward postures, where the plume may rise into your breathing zone.
  • Keep the work at a height where you can maintain a stable stance, because fatigue leads to mistakes.

This is general information, not a substitute for the safety rules of your employer, your jurisdiction and the manufacturer instructions.

How to Practice Each Position

A deliberate progression builds skill faster than jumping to the hardest test.

  1. Start flat. Get the arc length, angle and travel speed consistent on 1G and 1F before moving on.
  2. Add horizontal. Practice stringer beads on 2G until the bottom edge is clean.
  3. Move to vertical. Run uphill beads on 3G and learn to read the pool. Cut the coupons open or bend them to see what is really happening inside.
  4. Work overhead. Start with fillets in 4F, which are more forgiving, then move to 4G.
  5. Try pipe. Begin with 5G on thin wall pipe, then 6G, practicing the movement around the pipe with a dry run before welding.

Keep a log of settings, results and defects. Visual inspection, bend tests and, where available, radiography or ultrasonic testing will tell you more than looking at the surface does.

Practice with the consumables and process you will be tested with, and follow the written procedure for the test. A test on a different process or filler metal does not help your qualification, and may not match the equipment you will use.

Choosing Which Positions to Learn First

Most people benefit from a staged plan.

  • If you want shop fabrication work: master 1G, 2G and fillets in all positions, then 3G and 4G.
  • If you want pipework: build plate skills first, then move to 5G and 6G, since the plate skills transfer directly.
  • If you are a hobbyist or farm welder: focus on the positions you meet in practice, which are usually flat, horizontal and the occasional vertical repair.

There is no shame in specializing. A welder who is excellent in a defined range of positions is more valuable than one who is mediocre in all of them.

Conclusion

Welding positions are shorthand for how gravity treats a molten pool. The 1G, 2G, 3G and 4G codes describe plate groove welds from flat to overhead, 5G and 6G describe fixed pipe, and the F codes cover fillets. The ISO 6947 letter codes describe the same set of orientations with a few extra distinctions.

For welders, the position determines the technique, the difficulty of the test and the work you can legally and safely be assigned. For employers and inspectors, it defines what a qualification really covers. Learn the codes, check the standard that applies to your job, and build your skills from flat to overhead and from plate to pipe, one step at a time.

FAQ

Frequently asked questions

What does the G mean in 1G, 2G and 3G?

The G stands for groove weld, the type of weld that fills a prepared joint such as a butt joint. The number gives the orientation: 1 is flat, 2 is horizontal, 3 is vertical and 4 is overhead.

What is the difference between 1G and 1F?

Both are flat positions, but 1G is a groove weld in a butt joint and 1F is a fillet weld in a T-joint or lap joint. The same 1 to 4 numbering applies to fillets, so 3F is a vertical fillet and 4F is an overhead fillet.

Which welding position is the hardest?

For plate, the vertical and overhead positions are generally the hardest. For pipe, the 6G position is widely regarded as one of the most demanding common tests, and 6GR with a restriction ring is harder still. Difficulty also depends on the process and the material.

What is the difference between 5G and 6G?

In 5G the pipe is horizontal and fixed, and the welder works around it from bottom to top. In 6G the pipe is fixed at about 45 degrees, so the weld passes through all orientations at an incline, which makes it harder.

Does passing 6G qualify me for everything?

Not automatically. A pipe test in 6G is often accepted for a wide range of positions, but the actual range depends on the code, the process, the diameter, the thickness and any project requirements. Always read the qualification range in the governing standard.

What is the ISO equivalent of 3G?

The usual match is PF for vertical-up welding and PG for vertical-down welding. The correspondence is approximate, so check ISO 6947 and the qualification standard when you fill in documents.

Can I weld vertically downhill?

Yes, for some applications, mainly thin material and non-critical joints, because the bead is shallow and fast. Many structural procedures do not permit downhill progression on groove welds, so check the procedure before choosing a direction.

Which process is best for out-of-position welding?

There is no single answer. Stick welding, short-circuit or pulsed MIG, all-position flux-cored wires and TIG are all used out of position. The best choice depends on thickness, access, material and the qualification you need.

Should beginners learn every position?

Beginners should start flat and add positions in order. Learning all of them is useful, but it is reasonable to focus first on the positions you will meet in your job or in your target qualification.

Do I need different settings for each position?

Usually yes. Out-of-position welding normally uses lower heat input and smaller pools than flat welding, and some consumables are approved only for certain positions. The welding procedure and the consumable datasheet are the authority.

SOURCES

References

  1. ISO 6947:2019 Welding and allied processes - Welding positions - International Organization for Standardization, 2019. Defines welding positions for testing and production; page confirmed via search listing.
  2. ISO 9606-1:2012 Qualification testing of welders - Fusion welding - International Organization for Standardization, 2012. Qualification testing of welders for fusion welding of steels; page confirmed via search listing.
  3. AWS D1.1/D1.1M Structural Welding Code - Steel - American Welding Society. Structural steel welding code, includes welder qualification rules; page confirmed via search listing.
  4. Occupational Safety and Health Administration, Welding, Cutting, and Brazing - Hazards and Solutions - OSHA, accessed 2026-11-16.
  5. Occupational Safety and Health Administration, 1910.252 - General requirements - OSHA, accessed 2026-11-16.